Drying method:
The unit carries out internal circulation dehumidification in the drying room, and uses the latent heat of water condensation to heat the air in the drying room.
Application fields:
food, flowers, traditional Chinese medicine decoction pieces, aquatic products, industrial and other industries.
Conventional models:
7 P, 15P, 25P
Product advantages:
1. Easy installation; 
2. Closed drying; Clean and hygienic, zero pollution, zero emission; 
3. It is not affected by region, season, environmental temperature and humidity; All-weather drying, stable energy efficiency; 
4. It can recover the moisture of materials with high nutritional value.
| 
 Product name  | 
? | 
 Air source heat pump dryer  | 
|
| 
 type  | 
 /  | 
 Closed dehumidification all-in-one machine  | 
|
| 
 Product model  | 
 /  | 
 NCYNB-45IIDXS/01  | 
 NCYNB-45IIDXS/01  | 
| 
 Power form  | 
 V/Ph/Hz  | 
 380/3/50  | 
 380/3/50  | 
| 
 Ingress protection  | 
 /  | 
 IPX4  | 
 IPX4  | 
| 
 Type of protection against electric shock  | 
 /  | 
 Category I  | 
 Category I  | 
| 
 Dehumidification capacity (50°C/80%)  | 
 kg/h  | 
 52  | 
 52  | 
| 
 Dehumidification capacity (50°C/50%)  | 
 kg/h  | 
 30  | 
 30  | 
| 
 Rated operating power of the heat pump  | 
 kW  | 
 12.5  | 
 12.5  | 
| 
 Rated operating current of the heat pump  | 
 A  | 
 22  | 
 22  | 
| 
 Electric heating power  | 
 kW  | 
 12  | 
 12  | 
| 
 Maximum operating power of the heat pump  | 
 kW  | 
 30  | 
 30  | 
| 
 Maximum operating current of the heat pump  | 
 A  | 
 50  | 
 50  | 
| 
 Drying temperature  | 
 °C  | 
 20~75  | 
 20~75  | 
| 
 Maximum working pressure on the high/low pressure side  | 
 MPa  | 
 3.0/0.75  | 
 3.0/0.75  | 
| 
 Maximum working pressure on the drain/suction side  | 
 MPa  | 
 3.0/0.75  | 
 3.0/0.75  | 
| 
 The maximum pressure of the evaporator  | 
 MPa  | 
 4  | 
 4  | 
| 
 Refrigerant charge  | 
 kg  | 
 R134a/2X3.0  | 
 R134a/2X3.0  | 
| 
 noises  | 
 dB (A)  | 
 ≤70  | 
 ≤70  | 
| 
 Dimensions  | 
 mm  | 
 1610X1510X1885  | 
 1610X1510X1885  | 
| 
 net weight  | 
 kg  | 
 650  | 
|
| ? | 
 15HP closed rear air outlet  | 
 15HP closed upper air outlet  | 
|
The model, parameters and performance will be changed due to the improvement of the product, and the specific parameters are subject to the product nameplate.